1500V Solar Connector – 30A/45A IP67 PV Connector

The PV-EK04 1500v solar connector is a snap-in PV connector rated 1500V DC with 30A and 45A options. Its IP67 mated protection, UL-94 V0 housing and tin-plated copper alloy contacts suit Φ2.5 mm, Φ4 mm and Φ6 mm solar cables.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelPV-EK04
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of 1500v solar connector

The PV-EK04 1500v solar connector combines high voltage capability with a compact, tool-friendly snap-in design:

  • 1500V DC rating: built for high-voltage PV strings, with a 6 kV (50 Hz, 1 min) test voltage.
  • 30A and 45A current options: 30A for 2.5, 4 and 6 mm² (14, 12, 10 AWG); 45A for 4 and 6 mm² (12, 10 AWG).
  • IP67 when mated: sealed against dust and water immersion; IP2X when unmated.
  • Low contact resistance: 5 mΩ on the plug connectors for minimal power loss and heat.
  • Snap-in locking system: fast, secure assembly in the field.
  • Flame-retardant PC/PPO insulation: UL-94-V0 flame class and Safety Class II.
  • Wide temperature range: -40°C to +90°C (IEC) / -40°C to +194°F (UL), with an upper limiting temperature of +105°C (IEC).
  • Corrosion resistant: tin-plated copper alloy (brass) contacts; salt mist spray test, severity 5 (IEC 60068-2-52).
Metal crimp contacts (30A and 45A versions) – tin-plated copper alloy
Metal crimp contacts (30A and 45A versions) – tin-plated copper alloy

Commercial Applications 1500v solar connector

A 1500v solar connector lets designers use longer strings with fewer cables and combiner boxes, which lowers balance-of-system cost on large installations. The PV-EK04 is a solar panel dc connector suited to commercial and utility-scale projects where reliability and safety are priorities.

Applications & Use Cases

  • Utility-scale solar farms: module-to-module and string wiring in 1500V DC systems.
  • Commercial and industrial rooftops: PV array interconnection on warehouses, factories, and commercial buildings.
  • Ground-mount and tracker systems: outdoor cabling exposed to UV, rain, dust, and temperature swings.
  • Combiner boxes and inverters: string input and output connections for central and string inverters.
  • Energy storage and hybrid systems: DC-side wiring for solar-plus-storage projects.

Related use: it works as a dc solar connector for extension cables, jumper leads, and pre-assembled harnesses.

Technical Specifications of 1500v solar connector

The table below lists the full electrical, mechanical, and environmental data of the PV-EK04 1500v solar connector (standard: IEC 60068-2-52).

Parameter Value
Product model PV-EK04 (1500V)
Connector system Φ2.5 mm, Φ4 mm, Φ6 mm
Rated voltage 1500V DC
Rated current – 30A 2.5 mm², 4 mm², 6 mm² (14 AWG, 12 AWG, 10 AWG)
Rated current – 45A 4 mm², 6 mm² (12 AWG, 10 AWG)
Test voltage 6 kV (50 Hz, 1 min.)
Ambient temperature range -40°C to +90°C (IEC); -40°C to +194°F (UL)
Upper limiting temperature +105°C (IEC)
Degree of protection, mated IP67
Degree of protection, unmated IP2X
Contact resistance of plug connectors 0.5 mΩ
Safety class II
Contact material Brass / copper alloy, tin plated
Insulation material PC/PPO
Locking system Snap-in
Flame class UL-94-V0
Salt mist spray test, severity 5 IEC 60068-2-52

Dimensions and Wiring of 1500v solar connector

The PV-EK04 1500v solar connector housings measure 55.9 mm and 58.9 mm in length, with a width of 20.02 mm and a cable gland thread section of 11.89 mm. All dimensions are in millimetres.

Housing dimensions (mm)
Housing dimensions (mm)

Crimp contacts are supplied in 30A and 45A versions. Per the datasheet drawing, the 30A contacts measure 29 mm × 4 mm and 36 mm × 6 mm; the 45A contacts measure 35.2 mm and 32 mm in length.

Contact dimensions (mm): 30A and 45A versions
Contact dimensions (mm): 30A and 45A versions

Wiring guide

  • Select the cable: match the contact to the conductor size – 30A for 2.5/4/6 mm² (14–10 AWG), 45A for 4/6 mm² (12–10 AWG).
  • Strip and crimp: strip the insulation and crimp the contact onto the conductor with a suitable PV crimping tool.
  • Assemble: push the contact into the housing until the snap-in lock engages, then tighten the cable gland.
  • Mate: join the male and female connectors until fully locked to achieve IP67 protection.

Follow the installation instructions of the cable and tool manufacturers and local electrical codes.