Residual Current Circuit Breaker 6kA/10kA 63A AC Protection

Secures rigorous AC distribution networks with the Residual Current Circuit Breaker, delivering precise electro-magnetic leakage isolation. The ETL1-63 rccb circuit breaker safely manages 16-63A continuous loads, preventing dangerous electrical shocks across high-demand B2B installations.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETL1-63
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of the Residual Current Circuit Breaker

Engineered to instantaneously detect electrical leakage, this Residual Current Circuit Breaker guarantees uncompromised personnel safety and grid stability.

  • High-Capacity Disconnection: Safely clears conditional short-circuit currents up to 6kA (ETL1-63) or 10kA (ETL1-63H), protecting sensitive AC equipment.
  • Multi-Type Detection: Supports AC, A, A-SI, and A-S residual current types to handle complex loads and minimize nuisance tripping.
  • Visual Fault Indication: Features an integrated contacts position indication window (Green OFF / Red ON) for immediate operational verification.
  • Wiring Versatility: Accommodates bidirectional incoming routing utilizing standard cables, pin-type, or fork-type busbars up to 25mm² simultaneously.

Field Applications with the Residual Current Circuit Breaker

Deploying the ETL1-63 model provides mandatory electro-magnetic safety compliance across specialized commercial and industrial architectures.

Applications & Use Cases:

  • Residential Distribution: Acts as the primary rccb residual current circuit breaker for main circuit protection in high-density housing systems.
  • Commercial Buildings: Isolates leakage faults in complex lighting and central floor distribution architectures.
  • Industrial Equipment: Secures automated power supply lines against electrical leakage, protecting heavy machinery operators.
  • Public Facilities: Maintains strict electrical safety assurance in environments requiring rapid 10mA to 300mA sensitivity responses.

Technical Specifications for the Residual Current Circuit Breaker

Evaluate the comprehensive electro-magnetic parameters below to ensure this RCCB Breaker aligns precisely with your specific switchgear load calculations.

Certifications & Standards:

The ETL1-63 rigorously adheres to IEC/EN 61008-1 safety regulations, carrying CE and UKCA standard approvals for confident B2B global procurement.

Technical Data:

General Data
Standard IEC/EN 61008-1
Protection Ground fault
Type of trip Electro-magnetic type
Residual current type AC, A, A-SI, A-S
Break time at IΔn AC, A undelayed type: ≤100ms
A-SI delay: 10-300ms
A-S delay: 130-500ms
No. of poles 1P+N, 3P+N (N Pole on the right)
Insulation voltage (Ui) 500V
Rated voltage (Ue) 1P+N: 230/240V~ ; 3P+N: 400/415V~
Rated currents (In) 16, 25, 32, 40, 63A
Rated sensitivity currents (IΔn) 10mA (only for 1P+N 16A, 25A), 30, 100, 300mA
Rated residual making and breaking capacity (IΔm) 500A (In≤50A), 10In (In>50A)
Rated frequency 50/60Hz
Rated conditional short-circuit current (Inc=IΔc) ETL1-63: 6kA
ETL1-63H: 10kA
Rated impulse withstand voltage (Uimp) 4kV (1.2/50µs)
Dielectric test voltage 2kV (50/60Hz, 1 min.)
Mechanical Data & Installation
Electrical life / Mechanical life 2,000 Cycles / 4,000 Cycles
Contact position indicator Green OFF / Red ON
Protection degree IP20
Ambient temperature -25°C to +40°C
Terminal connection type Cable / Pin-type / Fork-type busbar
Max. terminal size for cable 16mm² flexible / 25mm² rigid
Max. tightening torque 2.5 N.m
Installation Mounting on 35mm DIN rail
Incoming method Bi-directional

RCD Type & Tripping Sensitivity:

RCD Type Characteristics
Type AC RCDs Detect slowly increasing sinusoidal AC residual currents.
Type A RCDs Detect AC leakage currents and pulsed DC leakage currents below 6mA.
Type S, G/SI RCDs Ensure tripping response to sinusoidal AC residual currents and effectively detect/trip pulsed DC residual currents, whether increasing suddenly or slowly.
Tripping Sensitivity (mA)
10mA Provides a higher level of protection for the human body; used in humid environments like swimming pools and bathrooms.
30mA Most commonly used protection level in homes and commercial buildings for socket protection.
100mA Used for equipment protection (e.g., AC systems, industrial equipment) where personal protection requirements are less strict.
300mA Mainly used for fire protection, distribution boards, and general protection of large electrical equipment.

Tripping Time & Breaking Characteristics:

Tripping Time Categories
Instantaneous (AC, A) Quickly disconnects circuits (≤300ms) to protect people from electric shock.
Short time delay (G/SI) Shorter trip times (10-300ms) to minimize damage where rapid power outage is required for equipment.
Selective S Longer tripping time (130-500ms) allowing downstream RCDs to trip first, avoiding unnecessary upstream power outages.
Breaking Time of Residual Current
In (A) IΔn (mA) 1 IΔn 2 IΔn 5 IΔn 5, 10, 20, 50, 100, 200, 500A
16, 25, 32, 40, 63 10, 30, 100, 300 0.3s 0.15s 0.04s 0.04s

Wiring Capacity:

Rated current In (A) Cross section area s (mm²) Tightening torque (N.m)
16 2.5 2.5
25 4.0 2.5
32 6.0 2.5
40 10.0 2.5
63 16.0 2.5

Dimensions and Wiring of the Residual Current Circuit Breaker

Verify exact enclosure compatibility for this Residual Current Circuit Breaker by referencing the structural indicators, standard 35mm DIN rail mounting footprints, and bi-directional incoming methods illustrated below.

Product Tips:

Residual Current Circuit Breaker 63

  1. PIN / Fork busbar compatible terminal blocks.
  2. Live line interface for bidirectional power routing.
  3. EAN-13 barcodes printed directly on the exterior shell for inventory traceability.
  4. Test button for routine mechanical and electrical verification.
  5. Neutral line interface (N Pole located on the right).
  6. Rated conditional short-circuit current 6kA, 10kA markings.
  7. Sensitivity to residual current AC, A, A-SI, A-S indicator.
  8. Contacts position indication window provides instant red/green operational status.

Dimension (mm):

Residual Current Circuit Breaker dima

Wiring Diagrams:

Residual Current Circuit Breaker wir

Request a Quote

Get pricing for ETL1-63

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp