10KA Circuit Breaker AC 1-63A 415V Overload Protection

Securing demanding AC distribution boards, the 10KA Circuit Breaker delivers precise 415V thermal-magnetic isolation. This rigorous AC Mini Circuit Breaker (model ETM1-63H) handles 1-63A continuous currents to prevent catastrophic panel failures.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETM1-63H
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Structural Features of the 10KA Circuit Breaker

Engineered from halogen-free thermoplastics, this 10ka mcb guarantees rapid fault clearance while maintaining strict RoHS compliance for demanding panel assemblies.

  • Ultimate Breaking Capacity: Safely interrupts high-stress overcurrents up to 10kA (Icu/Icn) at 415V AC, preventing structural panel failures.
  • Finger-Safe Terminals: Integrates IP20 connection protection alongside distinct red/green position indicators to visually verify operational status.
  • Versatile Termination: Accepts normal cables, pin-type, and fork-type busbars simultaneously to streamline the 10ka miniature circuit breaker wiring process.
  • Modular Expansion: Specifically configured to support the rapid mounting of auxiliary switches and fault signal contacts without modifying the main enclosure.

Field Applications for the 10KA Circuit Breaker

Deploying the robust ETM1-63H model prevents critical downtime across a broad spectrum of commercial and industrial AC network architectures.

  • Industrial Equipment: Isolates power supply lines for heavy machinery, functioning as a highly dependable 10ka industrial mcb against unpredictable AC starting currents.
  • Residential Distribution: Secures main AC circuits requiring a reliable 10ka breaker 120 240v setup for standard household load centers.
  • Commercial Buildings: Controls complex lighting circuits and central floor distribution systems that demand continuous operational power.
  • Public Facilities: Maintains uninterrupted energy distribution in strict accordance with recognized low-voltage switchgear safety protocols.

Technical Specifications with the 10KA Circuit Breaker

Evaluate the comprehensive engineering parameters below to ensure this 10 ka mcb aligns flawlessly with your specific AC load calculations and switchgear configurations.

Certifications & Standards:

The ETM1-63H complies rigorously with IEC 60898-1 for household installations and IEC 60947-2 for low-voltage controlgear, carrying CE and UKCA approvals for confident global procurement.

Technical Data:

General Data
ProtectionOvercurrent and short circuit
Type of tripThermal-magnetic
No. of poles1P, 2P, 3P, 4P
Rated operational voltage (Ue)1P: 110/230V, 120/240V, 230/240V, 240/415V AC
2P, 3P, 4P: 230/400V, 240/415V, 400/415V AC
Rated current (In)1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Rated frequency50/60Hz
Rated insulation voltage (Ui)440V
Rated impulse withstand voltage (Uimp)6kV (1.2/50µs)
Dielectric test voltage2kV (50/60Hz, 1 min.)
Fire resistance (glow-wire test)960±15°C (Enclosure); 650±10°C (Handle)
Pollution degree2
Data acc. to IEC/EN 60898-1
Rated short-circuit capacity (Icn)10kA
Rated service short-circuit breaking capacity (Ics)7.5kA
Energy limiting class3
Thermal tripping characteristics1.13xIn No tripping within an hour; 1.45xIn Tripping within an hour
Instantaneous tripping characteristicsB: 3In-5In; C: 5In-10In; D: 10In-20In
Data acc. to IEC/EN 60947-2
Rated ultimate short circuit breaking capacity Icu10kA
Rated service short circuit breaking capacity Ics7.5kA
Thermal tripping characteristics1.05xIn No tripping within an hour; 1.3xIn Tripping within an hour
Instantaneous tripping characteristics8In-12In
Mechanical Data & Installation
Electrical life / Mechanical life10,000 Cycles / 20,000 Cycles
Contact position indicationGreen OFF / Red ON
Protection degreeIP20
Operating ambient temperature-25°C ~ +55°C (with daily ≤35°C)
Terminal connection typeCable / Pin-type / Fork-type busbar
Terminal block / Max. tightening torqueScrew press-connected / 2.5 N.m
Max. terminal size for cable16mm² flexible / 25mm² rigid
Mounting type / Incoming methodMounting on 35mm DIN rail / Bi-Directional
Auxiliary for remote tripping or signaling
Available AccessoriesAuxiliary Contact, Alarm Contact, Shunt Release, Voltage Loss Release, Over-voltage Release, Undervoltage Release, Mechanical Interlock

Tripping Characteristic:

acc. to IEC/EN 60898-1

CurveRated CurrentNon-trip CurrentTrip CurrentTrip TimeAmbient Temperature
B1-63A1.13In1.45In≤1h / <1h30°C ± 5°C
C1-63A1.13In1.45In≤1h / <1hNormal temperature
D1-63A1.13In1.45In≤1h / <1hNormal temperature

ETM1-63H - acc. to IECEN 60947-1

acc. to IEC/EN 60947-2

Tripping CharacteristicInitial StateTest Current (A)Trip Time (t)Result to be obtainedAmbient Temperature
Thermal releaseCold state1.05In≥1hNo trip30 ± 2°C
Thermal releaseHot state (Follows above test)1.30In<1hTrip30 ± 2°C
Magnetic releaseCold state8In≤0.2sNo tripNormal temperature
Magnetic releaseCold state12In<0.2sTripNormal temperature

ETM1-63H - acc. to IECEN 60947-2

Temperature Derating Table:

In (A)-40°C-30°C-20°C-10°C0°C10°C20°C30°C40°C50°C60°C70°C
11.331.291.251.201.151.111.051.000.940.880.820.75
22.672.582.492.402.312.212.112.001.891.761.631.49
34.003.903.703.603.503.303.203.002.802.602.402.20
45.305.205.004.804.604.404.204.003.803.503.303.00
56.706.506.316.105.805.505.255.004.704.304.003.70
68.007.707.507.206.906.606.306.005.705.304.904.50
1013.312.912.512.011.511.110.510.09.408.808.207.50
1621.320.720.019.218.517.716.916.015.114.113.111.9
2026.725.824.924.023.122.121.120.018.917.616.314.9
2533.332.331.230.028.927.626.425.023.622.020.418.6
3242.741.339.938.537.035.433.732.030.228.226.123.9
4053.351.649.948.146.244.242.240.037.735.332.729.8
5066.764.562.460.157.755.352.750.047.144.140.837.3
6384.081.378.675.772.769.666.463.059.455.651.447.0

Dimensions & Wiring of the 10KA Circuit Breaker

Verify exact enclosure compatibility for this 10ka breaker by referencing the standard 35mm DIN rail mounting footprints and bi-directional incoming methods illustrated below.

Product Tips:

ETM1-63H Product Tips

  1. Bi-directional Routing: Supports reversible line and load terminal connections for maximum panel flexibility.
  2. Inventory Traceability: Features a clear pad-printed EAN-13 barcode directly on the outer housing.
  3. Maintenance Safety: Includes a dedicated handle lock position to secure the module during servicing.
  4. Load Management: Rated to handle continuous operational currents safely up to 63A.
  5. Busbar Compatibility: Designed to accept both PIN and Fork type busbars for versatile system integration.
  6. Visual Status Window: Explicit red/green contact position indicator for instant operational verification.

Wiring Diagram:

Wiring Diagram ETM1-63H_10kA_MCB

Dimensions:Dimensions ETM1-63H_10kA_MCB dim

Request a Quote

Get pricing for ETM1-63H

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp