6KA MCB AC 415V 63A Thermal-Magnetic Protection

Delivering robust AC 415V short-circuit isolation, this advanced 6ka mcb guarantees exact thermal-magnetic protection across commercial and industrial distribution nodes. The ETM1-63X series functions seamlessly as a heavy-duty 6ka miniature circuit breaker, handling rated currents up to 63A to aggressively prevent catastrophic electrical faults.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETM1-63X
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of the 6KA MCB

Constructed from environmentally compliant, halogen-free thermoplastics, this 6ka mcb ensures structural resilience while allowing full modular accessory expansion.

  • Robust Short-Circuit Defense: Delivers a confirmed rated short-circuit capacity (Icn) of 6kA, effortlessly clearing high-inrush fault currents in demanding panels.
  • Touch-Safe Terminals: Features IP20 finger-protected incoming and outgoing connections to prevent hazardous operator contact during maintenance.
  • Versatile Wiring Architecture: Designed with bi-directional incoming methods, accepting both flexible/rigid cables (up to 25mm²) and standard pin-type busbars.
  • Immediate Status Verification: Integrates a prominent red/green mechanical contact position indicating device for instant operational recognition.
  • Eco-Friendly Integrity: Utilizes state-of-the-art recyclable housing materials, fully conforming to strict international RoHS standards.

ETM1-63X Structural Design & Product Tips

The ergonomic shell incorporates specific structural features to simplify B2B installation and lifecycle management.

product tips ETM1-63X

  1. Reversible Connection: Supports bidirectional line and load terminal routing for highly flexible panel configurations.
  2. EAN-13 Barcodes: Pad-printed directly on the side shell for rapid B2B inventory scanning and precise warehousing tracking.
  3. Handle Lock Position: Specifically molded slot designed to secure the toggle with a mechanical padlock during vital line maintenance.
  4. Amperage Visibility: High-contrast front printing explicitly displaying the rated current up to 63A.
  5. Indication Window: Instant visual confirmation of the contact open/close position (green OFF / red ON).
  6. Breaking Capacity: Distinct 6kA metric marking on the faceplate for exact engineering verification.

Commercial Applications for the 6KA MCB

Deploying the ETM1-63X secures final distribution nodes, establishing a highly dependable iec 60898 mcb framework for any standard or complex setup.

Applications & Use Cases

  • Residential Power Systems: Functions as the core protective mcb 1p 32a 6ka in consumer units, safeguarding domestic appliances from overload damage.
  • Commercial Lighting Networks: Isolates extensive commercial lighting circuits efficiently, utilizing the mcb 1p 16a 6ka for standard office floors or retail complexes.
  • Industrial Equipment Protection: Secures AC power supply lines feeding robust industrial machinery, where a heavy-duty mcb 3p 32a 6ka is required to handle high starting currents.

Technical Specifications with the 6KA MCB

Evaluate the comprehensive thermal-magnetic tolerances below to seamlessly integrate this 6ka mcb into your AC electrical distribution panels.

General, Electrical & Mechanical Data

General & Technical Data (IEC/EN 60898-1)
Electrical Parameters
Protection Overcurrent and short circuit Type of trip Thermal-magnetic
No. of poles 1P, 2P, 3P, 4P Rated frequency 50/60Hz
Rated operational voltage (Ue) 1P: 110/230V, 120/240V, 230/400V, 240/415V AC
2P, 3P, 4P: 230/400V, 240/415V, 400/415V AC
Rated current (In) 1, 2, 3, 4, 5, 6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63A
Rated insulation voltage (Ui) 500V Rated impulse withstand (Uimp) 6kV (1.2/50μs)
Rated short-circuit capacity (Icn) 6kA Rated service breaking capacity (Ics) 6kA
Mechanical & Installation Data
Electrical / Mechanical life 4,000 Cycles / 20,000 Cycles Protection degree IP20
Terminal connection type Cable / Pin-type busbar Max. terminal size 16mm² flexible / 25mm² rigid
Operating ambient temp. -25°C ~ +55°C Fire resistance (glow-wire) 960±15°C (Enclosure)
Auxiliary Expansion Support Auxiliary Contact, Alarm Contact, Shunt Release, Voltage Loss Release, Under/Over-voltage Release, Mechanical Interlock (All Supported)

Tripping Characteristics

The instantaneous tripping parameters vary perfectly to accommodate low inrush circuits using an mcb 1p 6a 6ka up to high starting current motors.

Tripping Characteristic Curves 6ka mcb

Curve Type Rated Current Thermal Release (30°C ± 5°C) Magnetic Release (Normal Temp)
Non-trip (1.13In) Trip (1.45In) Trip Time Hold Current Trip Current Trip Time
B (Universal use) 1-63A ≤ 1h – < 1h 3In 5In ≥0.1s / <0.1s
C (Resistive/Inductive) 1-63A ≤ 1h – < 1h 5In 10In ≥0.1s / <0.1s
D (High inrush) 1-63A ≤ 1h – < 1h 10In 20In ≥0.1s / <0.1s

Temperature Derating Table

Use the correction factors below to adjust the rated current based on ambient panel temperatures.

Rated Current (A) Correction Factor for Ambient Temperature
-40°C -30°C -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
1 1.33 1.29 1.25 1.2 1.15 1.11 1.05 1 0.94 0.88 0.82 0.75
2 2.67 2.58 2.49 2.4 2.31 2.21 2.11 2 1.89 1.76 1.63 1.49
3 4.0 3.9 3.7 3.6 3.5 3.3 3.2 3 2.8 2.6 2.4 2.2
4 5.3 5.2 5.0 4.8 4.6 4.4 4.2 4 3.8 3.5 3.3 3.0
5 6.7 6.5 6.31 6.1 5.8 5.5 5.25 5 4.7 4.3 4.0 3.7
6 8.0 7.7 7.5 7.2 6.9 6.6 6.3 6 5.7 5.3 4.9 4.5
10 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10 9.4 8.8 8.2 7.5
16 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16 15.1 14.1 13.1 11.9
20 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20 18.9 17.6 16.3 14.9
25 33.3 32.3 31.2 30.0 28.9 27.6 26.4 25 23.6 22.0 20.4 18.6
32 42.7 41.3 39.9 38.5 37.0 35.4 33.7 32 30.2 28.2 26.1 23.9
40 53.3 51.6 49.9 48.1 46.2 44.2 42.2 40 37.7 35.3 32.7 29.8
50 66.7 64.5 62.4 60.1 57.7 55.3 52.7 50 47.1 44.1 40.8 37.3
63 84.0 81.3 78.6 75.7 72.7 69.6 66.4 63 59.4 55.6 51.4 47.0

Dimensions and Wiring of the 6KA MCB

Verify the exact modular DIN rail footprints and terminal spacing below to guarantee perfect panel fitment for this 6ka mcb.

Wiring Diagram

6ka mcb Wiring Diagram

Dimension (mm)

6ka mcb ETM1-63X Dimensions

Physical & Mounting Specifications

Poles Configuration Width (mm) Height (mm) Total Depth (mm)
1P 18 mm 81 mm 76 mm
2P 36 mm 81 mm 76 mm
3P 54 mm 81 mm 76 mm
4P 72 mm 81 mm 76 mm
Request a Quote

Get pricing for ETM1-63X

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp