AC Surge Protector 30kA In / 60kA Imax, Type 2 DIN Rail SPD

The ETU5-T2-60 AC surge protector delivers Type 2 / Class II protection with 30kA nominal and 60kA maximum discharge current (8/20μs). Built for TN-S, TN-C and TT low-voltage distribution systems, it features a keyed N-PE module and visual status indication.

 

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETU5-T2-60
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of the AC Surge Protector

The ETU5-T2-60 AC surge protector is designed for surge protection in low-voltage power distribution systems, defending against lightning-induced surges and switching overvoltages in building and industrial distribution applications. As a dependable ac power surge protector, it combines high discharge capacity with simple, safe maintenance.

  • Type 2 / Class II Protection: Nominal discharge current In 30kA and maximum discharge current Imax 60kA (8/20μs), L-N and N-PE.
  • Multi-System Compatibility: Supports TN-S, TN-C and TT network systems in 1P, 2P, 3P, 4P, 1P+NPE and 3P+NPE configurations.
  • Keyed N-PE Module Design: Helps prevent incorrect replacement while improving installation safety and maintenance convenience.
  • Pluggable Cartridge: Replace a worn module without removing the base or rewiring.
  • Visual Status Indication: Green window = operating normally; red = defect (L-N). Yellow window identifies the N-PE module.
  • Optional Remote Signaling: Potential-free contact (RC) reports module disconnection to a monitoring system – select the “S” version.
  • High Energy Protective Elements: High Energy MOV (L-N); High Energy MOV and GDT on 1P+NPE and 3P+NPE types. Response time ≤25ns (L-N) / ≤100ns (N-PE).
  • Uniform Panel Layout: Appearance and mounting dimensions are consistent with T Series devices, allowing side-by-side installation on a 35mm DIN rail (EN 60715).
  • Robust Enclosure: Thermoplastic housing rated UL94-V0, IP20 (built-in), operating range -40°C to +80°C.

Type Designation Guide

Example: ETU5-T2-60-2P275S

No. Code Meaning
1 E ETEK
2 T T series
3 U5 SPD series No.5
4 T2 Class II / Type 2
5 60 Imax: 60kA
6 2P No. of poles: 1P; 2P; 3P; 4P; 1PN (1P+NPE); 3PN (3P+NPE)
7 275 Uc: 150 (150V); 275 (275V); 320 (320V); 385 (385V)
8 S With remote signaling

Product Tipsac surge protector

Commercial Applications of the AC Surge Protector

Commercial and industrial sites depend on stable power. Installed at the distribution level, the ETU5-T2-60 AC surge protector limits transient overvoltages before they reach sensitive loads. The same module family is also widely specified as an ac spd for panel builders who need one coordinated Type 2 range.

Applications & Use Cases

  • Building Main Distribution: Incoming supply protection for commercial and residential complexes.
  • Branch Distribution Panels: Secondary protection in floor and sub-distribution boards.
  • Industrial Control Systems: Automation, machine control, and process panels.
  • Telecom & Data Rooms: Critical IT and communications equipment.

Technical Specifications of the AC Surge Protector

Review the electrical parameters below to match this type 2 surge protector to your system voltage, earthing arrangement, and coordination requirements. All values are taken from the ETU5-T2-60 datasheet.

Protection Level by Operating Voltage

Parameter 150V 275V 320V 385V
Max. continuous operating voltage (L-N) Uc 150V 275V 320V 385V
Voltage protection level Up (L-N)/(N-PE) 1.0kV/1.5kV 1.5kV/1.5kV 1.7kV/1.5kV 2.0kV/1.5kV
Voltage protection level Up at 5kA 0.6kV 1.0kV 1.2kV 1.4kV

 

General Electrical & Mechanical Data

Parameter Value
SPD type Type 2 / Class II
Standard IEC/EN 61643-11
Max. continuous operating voltage (N-PE) Uc 255V
Nominal discharge current (8/20μs) (L-N)/(N-PE) In 30kA
Maximum discharge current (8/20μs) (L-N)/(N-PE) Imax 60kA
Response time (L-N)/(N-PE) tA ≤25ns / ≤100ns
Operating temperature range Tu -40°C to +80°C
Max. back-up fuse 125A gL/gG
Operating state / fault indication Green/Red (L-N), Yellow (N-PE)
Cross-section area (min./max.) 4mm² / 35mm²
Mounting 35mm DIN Rail, EN 60715
Enclosure material Thermoplastic, UL94-V0
Degree of protection IP20 (built-in)
Remote contacts (RC) Optional
RC switching capacity AC: 250V/0.5A; DC: 250V/0.1A, 125V/0.2A, 75V/0.5A
RC conductor cross section (max.) 16 AWG (solid) / 1.5mm² (solid)

 

Configuration, Network System & Mode of Protection

No. of poles Network systems Mode of protection Protective elements
1P TN-S, TN-C, TT (only L-N) L-PE, N-PE (only TN-S), L-PEN, L-N High Energy MOV
2P TN-S L-PE, N-PE High Energy MOV
3P TN-C L-PEN High Energy MOV
4P TN-S L-PE, N-PE High Energy MOV
1P+NPE TT, TN-S L-N, N-PE High Energy MOV and GDT
3P+NPE TT, TN-S L-N, N-PE High Energy MOV and GDT

 

SPD Type Reference List

Poles 150V 275V 320V 385V
1P ETU5-T2-60-1P150 ETU5-T2-60-1P275 ETU5-T2-60-1P320 ETU5-T2-60-1P385
2P ETU5-T2-60-2P150 ETU5-T2-60-2P275 ETU5-T2-60-2P320 ETU5-T2-60-2P385
3P ETU5-T2-60-3P150 ETU5-T2-60-3P275 ETU5-T2-60-3P320 ETU5-T2-60-3P385
4P ETU5-T2-60-4P150 ETU5-T2-60-4P275 ETU5-T2-60-4P320 ETU5-T2-60-4P385
1P+NPE ETU5-T2-60-1PN150 ETU5-T2-60-1PN275 ETU5-T2-60-1PN320 ETU5-T2-60-1PN385
3P+NPE ETU5-T2-60-3PN150 ETU5-T2-60-3PN275 ETU5-T2-60-3PN320 ETU5-T2-60-3PN385

With Remote Signaling

Poles 150V 275V 320V 385V
1P ETU5-T2-60-1P150S ETU5-T2-60-1P275S ETU5-T2-60-1P320S ETU5-T2-60-1P385S
2P ETU5-T2-60-2P150S ETU5-T2-60-2P275S ETU5-T2-60-2P320S ETU5-T2-60-2P385S
3P ETU5-T2-60-3P150S ETU5-T2-60-3P275S ETU5-T2-60-3P320S ETU5-T2-60-3P385S
4P ETU5-T2-60-4P150S ETU5-T2-60-4P275S ETU5-T2-60-4P320S ETU5-T2-60-4P385S
1P+NPE ETU5-T2-60-1PN150S ETU5-T2-60-1PN275S ETU5-T2-60-1PN320S ETU5-T2-60-1PN385S
3P+NPE ETU5-T2-60-3PN150S ETU5-T2-60-3PN275S ETU5-T2-60-3PN320S ETU5-T2-60-3PN385S

Dimensions and Wiring of the AC Surge Protector

The ETU5-T2-60 ac surge protective device is built on an 18mm-per-pole DIN rail footprint, so panel builders can plan space and wiring quickly. Use the drawings below for mounting clearances, circuit layout, upstream fuse arrangement, and remote-signal connection.

Dimension (mm)

ac surge protector
Side view and front view of 1P, 2P, 3P and 4P modules (mm)
Item Dimension (mm)
Width – 1P / 2P / 3P / 4P 18 / 36 / 54 / 72
Width – 1P+NPE / 3P+NPE Same 2-module and 4-module layout as 2P and 4P (see connection diagrams)
Overall height (side view) 89.5
Height references (side view) 80.8 and 45.1
Depth references (side view) 50 and 67.4
Detail dimensions (side view) 11.1 and 8.3
Mounting 35mm DIN rail, EN 60715

Basic Circuit Diagram

ac surge protector
Basic circuit diagrams: 1P, 2P, 3P, 4P, 1P+NPE and 3P+NPE

Connection Diagram

F1 is the upstream protection fuse/breaker; F2 is the SPD back-up fuse (max. 125A gL/gG). Connect PE to the bottom ground terminal.

ac surge protector
Connection diagrams for all pole configurations

Maintenance and Remote Signal Terminal

ac surge protector
Left: module OK. Right: red indicator – replace module
Contacts Status
11-12 Closed / 11-14 Open SPD OK
11-12 Open / 11-14 Closed SPD disconnected – replace module
Request a Quote

Get pricing for ETU5-T2-60

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp