Type A or AC RCBO 6/10kA 63A 415V Leakage Isolation

Secures commercial AC distribution grids with the Type A or AC RCBO, delivering precise electro-magnetic leakage and overload isolation. The ETL3-63M effectively manages 6-63A loads, protecting critical B2B networks against severe electrical faults.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETL3-63M
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of the Type A or AC RCBO

Engineered to instantaneously interrupt 240/415V AC system faults, this Type A or AC RCBO guarantees rigorous equipment safety and personnel protection.

  • Dual Protection: Functions as a highly dependable rccb with overcurrent protection against overload, short circuit, and residual leakage faults.
  • High-Capacity Disconnection: Safely clears conditional short-circuit faults up to 6kA for the standard ETL3-63M, and 10kA for the heavy-duty ETL3-63MH variant.
  • Visual Fault Indication: Features a transparent trip status observation port alongside a visual leakage fault indication window (White for Normal, Blue for Leakage) to accelerate panel maintenance.
  • Wiring Versatility: Supports bidirectional incoming routing, seamlessly accommodating 16mm² flexible or 25mm² rigid cables simultaneously with PIN/Fork busbars.

Field Applications for AC Distribution

Deploying the ETL3-63M model minimizes critical downtime across specialized commercial and industrial architectures.

  • Industrial Equipment: Secures automated power supply lines against composite electrical leakage and overloads using the Type A or AC RCBO.
  • Commercial Buildings: Isolates multi-frequency faults effectively within complex lighting circuit control systems.
  • Public Facilities: Maintains strict electrical safety assurance in high-traffic environments requiring rapid 30mA to 300mA sensitivity responses.
  • Residential Distribution: Acts as the primary main circuit protection device for high-density housing load centers.

Technical Specifications with the Type A or AC RCBO

Evaluate the comprehensive electro-magnetic parameters below to ensure this Type A or AC RCBO aligns precisely with your specific B2B switchgear load calculations.

Certifications & Environmental Conditions:

The ETL3-63M rigorously adheres to IEC/EN 61009-1 safety regulations, operating reliably in ambient environments ranging from -25°C to +55°C.

Technical Data:

General Data
Standard IEC/EN 61009-1
Protection Ground fault, Overcurrent and short circuit
Type of trip Electro-magnetic type
Residual current type AC type AC residual current
A type residual AC and pulsating DC current
No. of poles 1P+N, 3P+N
Insulation voltage (Ui) 500V
Rated voltage (Ue) 1P+N: 230/240V~ ; 3P+N: 400/415V~
Rated currents (In) 6, 10, 16, 20, 25, 32, 40, 50, 63A
Rated sensitivity currents (IΔn) 30, 100, 300mA
Residual current off-time under (IΔn) <0.1s
Rated residual making and breaking capacity (IΔm) 500A (In≤50A)
10In (In>50A)
Rated frequency 50/60Hz
Rated short-circuit capacity (Icn) ETL3-63M: 6kA
ETL3-63MH: 10kA
Energy limiting class 3
Rated impulse withstand voltage (Uimp) 4kV (1.2/50µs)
Dielectric test voltage 2kV (50/60Hz, 1 min.)
Mechanical Data & Installation
Fire resistance (glow-wire test) 960±15°C (Enclosure)
650±10°C (Handle)
Electrical life / Mechanical life 4,000 Cycles / 8,000 Cycles
Contact position indicator Green OFF / Red ON
Ground fault indicator White: Normal
Blue: Leakage fault
Protection degree IP20
Ambient temperature -25°C ~ +55°C
Storage temperature -30°C ~ +70°C
Terminal connection type Cable / Pin-type / Fork-type busbar
Max. terminal size for cable 16mm² flexible / 25mm² rigid
Max. tightening torque 2.5 N.m
Installation Mounting on 35mm DIN rail
Incoming method Bidirectional

RCD Type & Tripping Sensitivity:

RCD Type Characteristics
Type AC RCDs Detect slowly increasing sinusoidal AC residual currents.
Type A RCDs Detect AC leakage currents and pulsed DC leakage currents below 6mA.
Tripping Sensitivity (mA)
30mA Most commonly used protection level in homes and commercial buildings, suitable for socket protection in general residential environments, offices, and commercial places.
100mA Usually used in situations where personal protection requirements are not as strict as 30mA, or for equipment protection, such as air conditioning systems, industrial equipment, etc.
300mA Mainly used for fire protection, such as distribution boards and general protection of large electrical equipment.

Tripping Characteristics:

Curve Rated Current Thermal Release Magnetic Release
Non-trip (≤1h) Trip (<1h) Hold Current (≥0.1s) Trip Current (<0.1s) Trip Time
B 6-63A 1.13xIn 1.45xIn 3xIn 5xIn <0.1s
C 6-63A 1.13xIn 1.45xIn 5xIn 10xIn <0.1s

Type A or AC RCBO

Breaking Time of Residual Current:

Max. breaking time
In (A) IΔn (mA) 1 IΔn 2 IΔn 5 IΔn 5, 10, 20, 50, 100, 200, 500A
6, 10, 16, 20, 25, 32, 40, 50, 63 30, 100, 300 0.3s 0.15s 0.04s 0.04s

Temperature Derating Table:

In (A) -40°C -30°C -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
6 8.0 7.7 7.5 7.2 6.9 6.6 6.3 6.0 5.7 5.3 4.9 4.5
10 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10.0 9.4 8.8 8.2 7.5
16 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16.0 15.1 14.1 13.1 11.9
20 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20.0 18.9 17.6 16.3 14.9
25 33.3 32.3 31.2 30.0 28.9 27.6 26.4 25.0 23.6 22.0 20.4 18.6
32 42.7 41.3 39.9 38.5 37.0 35.4 33.7 32.0 30.2 28.2 26.1 23.9
40 53.3 51.6 49.9 48.1 46.2 44.2 42.2 40.0 37.7 35.3 32.7 29.8
50 66.7 64.5 62.4 60.1 57.7 55.3 52.7 50.0 47.1 44.1 40.8 37.3
63 84.0 81.3 78.6 75.7 72.7 69.6 66.4 63.0 59.4 55.6 51.4 47.0

Dimensions and Wiring for the Type A or AC RCBO

Verify exact enclosure compatibility for this rccb with overcurrent protection by referencing the structural indicators, standard 35mm DIN rail mounting footprints, and bi-directional incoming methods illustrated below.

Product Tips:

Product Tips Type A or AC RCBO

  1. Dual-compatible terminal blocks for seamless PIN or Fork busbar integration.
  2. Live line interface optimized for bidirectional incoming power structures.
  3. Pad-printed EAN-13 barcodes ensuring accurate B2B inventory tracking.
  4. Integrated handle lock position to secure the module during panel maintenance.
  5. Explicit 6kA/10kA breaking capacity markings for rapid capacity verification.
  6. Dedicated neutral line interface directly on the device housing.
  7. Front-mounted test button for routine mechanical and electrical validation.
  8. Residual current trip indicator for immediate overcurrent or leakage fault diagnosis.
  9. Clear sensitivity indicator designating suitability for residual current AC and A types.
  10. Contacts position indication window providing instant visual operational status.

Dimension (mm):

Type A or AC RCBO Dimension

Wiring Diagrams:

Type A or AC RCBO Wiring Diagrams

Request a Quote

Get pricing for ETL3-63M

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp