Dual Power Automatic Transfer Switch AC 400V 16A–630A

The EKS2T dual power automatic transfer switch is a PC class ATS for AC 50/60Hz, 400V systems from 16A to 630A. It switches reliably between grid, backup or generator supplies, supports fire linkage, and protects hospitals, banks and high-rise buildings from power loss.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelEKS2T
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of Dual Power Automatic Transfer Switch

This dual power automatic transfer switch is a PC grade (three-sectional) automatic conversion switchgear that switches between two power supplies when an abnormality occurs on one of them, protecting the reliability and safety of the power supply.

  • Three working positions: common (I) switch-in, standby (II) switch-in, and disconnection (0), which also supports fire linkage and infrequent on-off power systems.
  • Five controller types (A to E): A basic type, B firefighting type, and C/D/E intelligent types, so the switch can be matched to simple or complex projects.
  • Manual and automatic operation: manual rotating wheel plus a manual/automatic toggle switch; remote control is available on the higher-spec controllers.
  • Flexible conversion modes: self-throwing self-resetting (default) or self-throwing non-self-resetting for mutual backup between two grids.
  • Adjustable protection (Types B to E): under-voltage conversion 165–217V, over-voltage conversion 243–298V, voltage measuring range 4–300V, and under/over-frequency detection at 40–60Hz.
  • Adjustable delays: conversion delay and return delay, both continuously adjustable from 0 to 180 s.
  • Generator and fire control: one set of relay dry contacts for generator start, plus firefighting forced-setting “0” with one passive contact input and one N.O. passive signal feedback.
  • Phase-loss detection: three-phase (A, B, C) detection on advanced controllers; Type A monitors three phases on the common supply and a single phase on the backup supply.
  • Clear status indication: LED status display, with an LCD screen option on the intelligent controllers; mechanical position indicator on the switch body.
  • Communication and installation options: RS485 communication on Type D/E controllers; integrated type (no display screen) or split type (with display screen).
Part Function
Common power supply I at incoming end Incoming terminals for the common (main) source
Common power supply II at incoming end Incoming terminals for the standby (backup) source
Mechanical indication Shows the current switch position
Load connection terminal Output terminals to the load
Manual operation rotating wheel Manual switching between I, 0 and II
Manual / automatic toggle switch Selects manual or automatic operation
Switch status indicator Shows the working state of the switch
Product information Nameplate: model, Ue, Ie, Uimp, Iq, PC class AC-33iB

Commercial Applications of Dual Power Automatic Transfer Switch

Where a power cutout is not allowed, a dual power automatic transfer switch keeps critical loads running by moving automatically to the healthy supply. The EKS2T is mainly applied in hospitals, shopping malls, banks, chemical plants, metallurgical plants, high-rise buildings, military facilities, and firefighting systems.

Applications & Use Cases

  • Hospitals and medical facilities: continuous supply to life-critical equipment, with automatic changeover from mains to backup.
  • Banks and shopping malls: uninterrupted power for security, lighting, payment, and control systems.
  • Chemical and metallurgical plants: reliable supply for continuous-process equipment where an outage is a safety or production risk.
  • High-rise buildings and firefighting: fire-linkage control forces the switch to the “0” position through a passive contact input; the generator start signal is available through relay dry contacts.
  • Military facilities: dependable supply switching for important sites where power cutout is not allowed.
  • Grid to grid: Power supply I priority (self-throwing, self-resetting, A-9-001) or mutual backup (self-throwing, non-self-resetting, A-9-000).
  • Grid to generator: the switch starts the generator signal on grid failure, waits for the generator warm-up delay, transfers to supply II, and returns to the grid after recovery.

Technical Specifications of Dual Power Automatic Transfer Switch

The table below lists the main electrical data of this dual power automatic transfer switch, designed for IEC60947-6-1 for AC 50/60Hz power systems.

Electrical Data

Parameter EKS2T-125 EKS2T-250 EKS2T-630
Rated working current (Ie) 16, 20, 32, 40, 50, 63, 80, 100, 125A 125, 160, 200, 225, 250A 250, 315, 350, 400, 500, 630A
Rated power supply voltage (Us) AC 230V AC 230V AC 230V
Rated insulation voltage (Ui) 800V 800V 800V
Rated impulse withstand voltage (Uimp) 8kV 8kV 8kV
Rated short-circuit making capacity 17kA peak 26kA peak (see note) 26kA peak (see note)
Rated limited short-circuit current (Iq) 120kA 120kA 120kA
Contact conversion time 0.58s 0.56s 0.9s
Conversion action time 1.35s 1.3s 2.0s

Controller Functions

Function Details by controller type
Rated control power supply AC 230V 50/60Hz (all types)
Auxiliary working voltage None on Type A/B; DC 24V on Type C/D/E
Voltage measuring range 4–300V (Types B to E)
Working positions Three: common switch-in, backup switch-in, both switch-off
Way of operation Manual, automatic; remote control on higher types
Way of display LED status display; LCD screen on intelligent types
Way of conversion Self-throwing self-resetting (default); self-throwing non-self-resetting optional
Under-voltage / over-voltage conversion 165–217V / 243–298V adjustable
Under-frequency / over-frequency detection 40–60Hz adjustable
Timing start function Timing conversion / timing start generator
Conversion delay / return delay 0–180s continuously adjustable
Phase-loss detection Type A: common three phases, backup single phase; advanced types: three phases (A, B, C)
Generator control One set of relay dry contacts (Types B to E)
Firefighting linkage control Forced setting “0”: one passive contact input, one N.O. passive signal feedback
Communication RS485 on Type D/E; default none, optional
Way of installation Integrated (no display screen) or split (with display screen)

Normal Working Conditions

Item Requirement
Ambient temperature -5°C to +40°C; 24-hour average not above +35°C
Relative humidity Max 50% at +40°C; monthly maximum 90% at lower temperatures
Altitude Not exceeding 2000 meters
Pollution level Level 3
Usage category AC-33iB
Electromagnetic environment Environment A (protective measures needed in environment B)
Standard IEC60947-6-1

 

Dimensions and Wiring of Dual Power Automatic Transfer Switch

Check the installation and handle space sizes below before mounting this dual power automatic transfer switch, and use the terminal definitions to wire each controller type correctly.

Dimensions (mm)

Dual Power Automatic Transfer Switch

Dimension 125 250 630/3P 630/4P
External dimension
A 242 315 417 475
B 120 170 230 230
H 115 146 202 202
Installation dimension
A1 116 298.5 386.5 444.5
B2 106 155 203 203
H1 15.5 20 16.5 16.5
H2 33 44 62 62
H3 82.2 101 130 130
L1 18.5 26 48 48
L2 19 24 32.6 32.6
C 83 121 173 173
E 21 25 27 27
V 16.6 22 45.5 45.5
P 25 35 58 58
D Φ4.5 Φ6.3 Φ8.5 Φ8.5
M M6 M8 M10 M10
Handle space size
G 196 246 305 305
R 106 137 163 163
Q 194 235 240 240

Definition of Terminal

Terminal numbers for each controller type. “✓” means the terminal is present on that controller.

Terminal Function Type A Type B Type C Type D/E
101 Common zero-line ✓ ✓ ✓ ✓
102 Common power supply ✓ ✓ ✓ ✓
103 Common switch-in ✓ ✓ ✓ ✓
201 Backup zero-line ✓ ✓ ✓ ✓
202 Backup power supply ✓ ✓ ✓ ✓
203 Backup switch-in ✓ ✓ ✓ ✓
301 DC24V+ — — ✓ ✓
302 DC24V- — — ✓ ✓
401 / 402 Firefighting passive input — ✓ ✓ ✓
403 / 404 Firefighting passive output — ✓ ✓ ✓
501 NO end of generator — ✓ ✓ ✓
502 Common end of generator — ✓ ✓ ✓
503 NC end of generator — ✓ ✓ ✓
601 RS485 A+ — — — ✓
602 RS485 B- — — — ✓
603 RS485 GND — — — ✓