125A DC Circuit Breaker 1000V 6kA Overcurrent Isolation

Safeguards heavy-duty photovoltaic structures with the 125A DC Circuit Breaker, delivering precise 1000VDC thermo-magnetic protection. The EKM1-125DC DC Mini Circuit Breaker handles 80-125A continuous direct currents to secure demanding energy storage systems against catastrophic overloads.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelEKM1-125DC
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Structural Features of the 125A DC Circuit Breaker

Engineered to rapidly interrupt high-voltage direct current faults, this 125A DC Circuit Breaker ensures absolute polarity disconnection for large-scale solar architectures.

  • Voltage Scalability: Operates safely across 250VDC (1P), 500VDC (2P), and 1000VDC (4P) configurations to match specific 125a dc breaker requirements.
  • High-Capacity Interruption: Clears severe fault currents up to 6kA (Icn), shielding energy storage battery banks from destructive overloads.
  • Advanced Tripping Mechanisms: Incorporates a default 8-12In instantaneous trip, with optional Z, L, and K curves to manage unique 125 amp dc circuit breaker inrush profiles.
  • Visual Status Indication: Features an integrated green (OFF) and red (ON) contact position window for immediate maintenance verification inside the panel.

Field Applications for DC Distribution

Deploying this robust 125A DC Circuit Breaker minimizes critical downtime across specialized commercial direct current networks.

  • Photovoltaic Arrays: Isolates solar string lines effectively, functioning as a mandatory main disconnect for commercial solar farms.
  • Energy Storage Systems (ESS): Secures large-scale battery banks against destructive overcurrents during repetitive charging cycles using this 125 amp dc breaker.
  • Direct Current Panels: Provides central circuit isolation and dependable dc breaker 125 amp performance for high-load automated control panels.

Technical Specifications with the 125A DC Circuit Breaker

Evaluate the comprehensive electrical parameters below to ensure this 125A DC Circuit Breaker aligns precisely with your B2B switchgear calculations and cable sizing up to 35mm².

Certifications & Standards

The EKM1-125DC adheres strictly to IEC/EN 60947-2 regulations for low-voltage controlgear, operating reliably in ambient temperatures from -5°C to +40°C with up to 95% maximum non-condensing humidity.

Technical Data

General Data
Standard IEC/EN 60947-2
Protection Overcurrent and short circuit
Type of trip Thermo-magnetic
No. of poles 1P, 2P, 4P
Rated voltage (Ue) 250VDC (1P), 500VDC (2P), 1000VDC (4P)
Insulation voltage 500V
Rated currents (In) 80, 100, 125A
Rated short-circuit capacity (Icn) 6kA
Rated impulse withstand voltage (Uimp) 4kV (1.2/50µs)
Dielectric test voltage 3kV (50/60Hz, 1 min.)
Mechanical Data & Installation
Electrical life 4,000 Cycles
Mechanical life 10,000 Cycles
Contact position indicator Green OFF / Red ON
Protection degree IP20
Ambient temperature -5°C to +40°C (Max. 95% humidity)
Terminal connection type Cable
Max. terminal size for cable 35mm²
Max. tightening torque 2.5 N.m
Installation Mounting on 35mm DIN rail
Incoming method According to the wiring diagram (Polarity specific)

Tripping Characteristic:

Tripping Curve Thermal Tripping Characteristics Instantaneous Tripping Characteristics
Default Curve 1.05In: no tripping within 2h
1.30In: tripping within 2h
8In – 12In
Z Curve (Optional) 1.05In: no tripping within 2h
1.30In: tripping within 2h
3In – 5In
L Curve (Optional) 1.05In: no tripping within 2h
1.30In: tripping within 2h
6In – 10In
K Curve (Optional) 1.05In: no tripping within 2h
1.30In: tripping within 2h
10In – 14In

125A DC Circuit Breaker cruve

Temperature Derating Table:

In (A) -40°C -30°C -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
80 106.4 103.2 100.0 96.0 92.0 88.8 84.0 80.0 75.2 70.4 65.6 60.0
100 133.0 129.0 125.0 120.0 115.0 111.0 105.0 100.0 94.0 88.0 82.0 75.0
125 166.3 161.3 156.3 150.0 143.8 138.8 131.3 125.0 117.5 110.0 102.5 93.8

Dimensions and Wiring of the 125A DC Circuit Breaker

Verify exact enclosure compatibility for the 125A DC Circuit Breaker by referencing the standardized 35mm DIN rail mounting footprints and polarity-specific incoming methods illustrated below.

Dimension (mm)

125A DC Circuit Breaker Dimension

Circuit Diagrams

Circuit Diagrams

Request a Quote

Get pricing for EKM1-125DC

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp