Type A or Type AC RCBO 415V 63A Leakage & Overcurrent 6kA

Designed to guarantee absolute commercial electrical safety, this Type A or Type AC RCBO masterfully combines overcurrent, short circuit, and earth fault leakage protection into one highly efficient unit. The ETL3-63 series functions as a strictly dependable residual current circuit breaker with overcurrent protection, specifically optimized to monitor AC and pulsating DC residual currents across heavy-duty residential and industrial power systems up to 63A.

Request a Quote

Pricing is quoted per order — tell us your quantity and destination and our sales team will respond with a full offer.

ModelETL3-63
AvailabilityIn stock
  • CE & TUV certified
  • Worldwide shipping
  • OEM & ODM support

Product Features of the Type A or Type AC RCBO

Constructed for rigorous electrical environments, this Type A or Type AC RCBO leverages a precise electronic ground fault trip mechanism paired with a robust thermal-magnetic core.

  • Dual Leakage Detection: Effectively detects standard sinusoidal AC residual currents (Type AC) alongside pulsating DC leakage currents below 6mA (Type A).
  • High Short-Circuit Defense: Achieves a formidable 6kA rated short-circuit capacity (Icn) or an upgraded 10kA (ETL3-63H), effortlessly clearing high-inrush fault currents.
  • Advanced Visual Diagnostics: Integrates a blue/white residual current trip indicator alongside a red/green contact position window for instant, error-free fault recognition.
  • Flexible Wiring Architecture: Fully supports bidirectional power routing and accepts cables up to 25mm² (rigid) alongside standard pin and fork-type busbars.
  • Eco-Conscious Durability: Built from premium halogen-free, RoHS-compliant thermoplastics, ensuring structural integrity and a massive 8,000-cycle mechanical lifespan.

ETL3-63 Configuration & Design Tips

The ergonomic IP20 DIN-rail mountable shell incorporates clear visual diagnostics to streamline heavy-duty B2B installations and safety verification.

ETL3-63 Product Tips type a or type ac rcbo

  1. PIN / Fork Busbar Ready: Specially designed terminal cavities to accept robust busbar connections for parallel panel routing.
  2. Live Line Interface: Distinctly separated phase connections engineered for maximum AC electrical isolation.
  3. EAN-13 Barcodes: Pad-printed directly on the side enclosure for rapid B2B inventory scanning and warehousing tracking.
  4. Handle Lock Position: Molded slot designed to securely lock the toggle with a mechanical padlock during vital line maintenance.
  5. Short-Circuit Capacity: Distinct 6kA or 10kA metric marking explicitly pad-printed on the faceplate for exact engineering verification.
  6. Neutral Line Interface: Clearly marked N-pole positioned precisely for standard industrial panel integration.
  7. Test Button: Integrated monthly test switch to instantly verify the internal electronic tripping integrity.
  8. Residual Current Trip Indicator: Specialized visual window (White: Normal / Blue: Leakage) to instantly identify earth fault causes.
  9. Sensitivity to Residual Current AC, A: Faceplate markings indicating precise Type A and Type AC detection parameters.
  10. Contacts Position Window: Clear red/green mechanical contact position indicator for instant operational status recognition.

Applications for the Type A or Type AC RCBO

Deploying the ETL3-63 secures vital single and three-phase distribution nodes, acting as a highly dependable residual current circuit breaker with overcurrent protection for demanding commercial infrastructure.

Applications & Use Cases

  • Commercial Lighting Networks: Controls and comprehensively isolates extensive lighting circuits within large-scale office buildings and retail complexes.
  • Industrial Equipment Protection: Secures robust AC power supply lines feeding specialized industrial machinery against simultaneous overloads and earth faults.
  • Residential Power Systems: Functions as the primary protective unit in main consumer distribution boards, safeguarding domestic appliances from severe electrical damage.

Technical Specifications for the Type A or Type AC RCBO

Evaluate the exact electronic and thermo-magnetic parameters below to seamlessly integrate this Type A or Type AC RCBO into your specialized distribution panels.

General, Electrical & Mechanical Data

General & Technical Data (IEC/EN 61009-1)
Electrical & Protection Parameters
Protection Ground fault, Overcurrent and short circuit Type of trip Ground fault: Electronic | Overload: Thermal-magnetic
No. of poles 1P+N, 3P+N Rated frequency 50/60Hz
Rated voltage (Ue) 1P+N: 230/240V~ | 3P+N: 400/415V~ AC Energy limiting class 3
Rated currents (In) 6, 10, 16, 20, 25, 32, 40, 50, 63A
Rated sensitivity currents (IΔn) 10, 30, 100, 300mA Residual current off-time ≤ 0.1s
Rated short-circuit capacity (Icn) 6kA (ETL3-63) | 10kA (ETL3-63H) Rated residual capacity (IΔm) 500A (In≤50A) | 10In (In>50A)
Insulation voltage (Ui) 500V Rated impulse withstand (Uimp) 4kV (1.2/50μs)
Mechanical & Installation Data
Electrical / Mechanical life 4,000 Cycles / 8,000 Cycles Protection degree IP20
Terminal connection type Cable / Pin-type / Fork-type busbar Max. tightening torque 2.5 N.m
Operating ambient temp. -25°C ~ +55°C Fire resistance (glow-wire) 960±15°C (Enclosure)

RCD Type Classifications

The ETL3-63 provides precise detection tailored for standard and pulsating fault currents.

type a or type ac rcbo RCD Type

Tripping Sensitivity Applications

Select the precise sensitivity rating (IΔn) to match specific personnel and equipment protection requirements.

Sensitivity Ratings (IΔn)
10mA Provides a higher level of protection for the human body, used in situations with very high requirements like swimming pools and humid environments.
30mA Most commonly used for personnel protection in homes and commercial buildings, suitable for general socket protection.
100mA Usually used in situations where personal protection is less strict, focusing heavily on equipment protection like air conditioning systems.
300mA Mainly used for superior fire protection, acting as general protection for massive distribution boards.

Breaking Time of Residual Current

Understand the exact break times for varying fault multipliers.

In (A) IΔn (mA) Max. Breaking Time at:
IΔn 2IΔn 5IΔn 5, 10, 20, 50, 100, 200, 500A
6, 10, 16, 20, 25, 32, 40, 50, 63 10, 30, 100, 300 0.1s 0.08s 0.04s 0.04s

Thermo-Magnetic Tripping Characteristics

The thermal and magnetic release parameters adapt perfectly to diverse load environments.

type a or type ac rcbo Tripping Characteristic Curve

Curve Type Rated Current Thermal Release (Condition) Magnetic Release (Condition)
Non-trip (1.13In) Trip (1.45In) Trip Time (30°C ± 5°C) Hold Current Trip Current Trip Time (Normal Temp)
B (Universal use) 6-63A ≤ 1h – < 1h 3In 5In ≥0.1s / <0.1s
C (Resistive/Inductive) 6-63A ≤ 1h – < 1h 5In 10In ≥0.1s / <0.1s

Temperature Derating Table

Use the correction factors below to accurately adjust the continuous rated current based on ambient installation temperatures.

Rated Current (A) Correction Factor for Ambient Temperature
-40°C -30°C -20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
6 8.0 7.7 7.5 7.2 6.9 6.6 6.3 6 5.7 5.3 4.9 4.5
10 13.3 12.9 12.5 12.0 11.5 11.1 10.5 10 9.4 8.8 8.2 7.5
16 21.3 20.7 20.0 19.2 18.5 17.7 16.9 16 15.1 14.1 13.1 11.9
20 26.7 25.8 24.9 24.0 23.1 22.1 21.1 20 18.9 17.6 16.3 14.9
25 33.3 32.3 31.2 30.0 28.9 27.6 26.4 25 23.6 22.0 20.4 18.6
32 42.7 41.3 39.9 38.5 37.0 35.4 33.7 32 30.2 28.2 26.1 23.9
40 53.3 51.6 49.9 48.1 46.2 44.2 42.2 40 37.7 35.3 32.7 29.8
50 66.7 64.5 62.4 60.1 57.7 55.3 52.7 50 47.1 44.1 40.8 37.3
63 84.0 81.3 78.6 75.7 72.7 69.6 66.4 63 59.4 55.6 51.4 47.0

 

Dimensions and Wiring of the Type A or Type AC RCBO

Verify the exact modular DIN rail footprints and wiring capacities below to guarantee perfect panel fitment for this Type A or Type AC RCBO.

Circuit Diagrams (1P+N & 3P+N)

type a or type ac rcbo ETL3-63 Circuit Diagram

Physical & Mounting Specifications

type a or type ac rcbo ETL3-63 Dimensions

Poles Configuration Width (mm) Height (mm) Total Depth (mm)
1P+N 36 mm 83 mm 70.1 mm
3P+N 72 mm 102.5 mm 70.1 mm
Request a Quote

Get pricing for ETL3-63

Complete the form and our sales engineers will reply with pricing, lead time and certification documents.

Chat on WhatsApp